,c##OTHER##,b##OTHER##,a##OTHER##,Weight (kg)##MASS##KILOGRAMS,Voltage##ELECTRICAL_POTENTIAL##VOLTS,SIEMENS ROOM PANEL##OTHER##,REGIN ROOM PANEL##OTHER##,Power Cunsumption##ELECTRICAL_APPARENT_POWER##VOLT_AMPERES,OTOMASYON##OTHER##,L/4##LENGTH##MILLIMETERS,HUMIDITY SENSOR##OTHER##,FILTER##OTHER##,Equipment External Static Pressure (Pa)##HVAC_PRESSURE##PASCALS,Designe External Static Pressure##HVAC_PRESSURE##PASCALS,Design Feasible##OTHER##,DPS##OTHER##,Current(A)##ELECTRICAL_CURRENT##AMPERES,CONSTANT FLOW##OTHER##,CO2 SENSOR##OTHER##,Air Flow##HVAC_AIR_FLOW##CUBIC_METERS_PER_HOUR,Actual Air Flow##HVAC_AIR_FLOW##CUBIC_METERS_PER_HOUR,2.Exhaust Side M6 Filter##OTHER##,2.Exhaust Side M5 Filter##OTHER##,URL-TR##OTHER##,Gate4##OTHER##,Gate3##OTHER##,Gate2##OTHER##,Gate1##OTHER##,G1##LENGTH##MILLIMETERS,G##LENGTH##MILLIMETERS,F1##LENGTH##MILLIMETERS,Ele Width##LENGTH##MILLIMETERS,Ele Height##LENGTH##MILLIMETERS,E##LENGTH##MILLIMETERS,D##LENGTH##MILLIMETERS,B/2##LENGTH##MILLIMETERS,URL##OTHER##,2.Exhaust Side F9 Filter##OTHER##,E/2##LENGTH##MILLIMETERS,Product ID##OTHER##,Model##OTHER##,Material Black##OTHER##,Manufacturer##OTHER##,2.Exhaust Side F8 Filter##OTHER##,C##LENGTH##MILLIMETERS,2.Exhaust Side F7 Filter##OTHER##,2.Supply Side M6 Filter##OTHER##,2.Supply Side M5 Filter##OTHER##,F##LENGTH##MILLIMETERS,Description##OTHER##,2.Supply Side F7 Filter##OTHER##,A##LENGTH##MILLIMETERS,Con W##LENGTH##MILLIMETERS,2.Supply Side F8 Filter##OTHER##,2.Supply Side F9 Filter##OTHER##,Body Material##OTHER##,Base H##LENGTH##MILLIMETERS,Base B##LENGTH##MILLIMETERS,Base A##LENGTH##MILLIMETERS,W##LENGTH##MILLIMETERS,H##LENGTH##MILLIMETERS,B##PIPE_SIZE##MILLIMETERS,Access Material##OTHER##,L##LENGTH##MILLIMETERS K41.070.1.T.X,1084.2,-0.0425,-0.00002,832,380,1,1,3700,1,643.3333333,1,"ISO Epm2,5",200,164.9,0,1,5.8,1,1,"5,800","5,800",1,1,https://www.doguiklimlendirme.com/d/isi-geri-kazanim-cihazlari/four-rter-rotorlu-tip-enerji-geri-kazanim-cihazi,1,1,1,1,800,790,695,307.5,154,780,640,615,https://www.doguiklimlendirme.com/d/heat-recovery-units/four-rter-rotary-type-heat-energy-recovery-unit,1,230,K41.070.1.T.X,RTER-070-1-TOP,Metal Black,DOGU HVAC,1,1330,1,1,1,685,ROTARY TYPE HEAT RECOVERY UNIT-RTER-1 switchable duct connection(top or side) and interchangeable service doors with new fan positioning acc.to new regulation for Rotary wheeled units(to prevent the leakage of exhaust air to suplly air).,1,500,700,1,1,Metal White,100,1080,1158,1230,1540,460,Gray Plastic,2895 K41.200.1.T.X,1069.6,0.0249,-0.000004,2160,380,1,1,13500,1,784.4444444,1,"ISO Epm2,5",200,161.25,0,1,20.6,1,1,"18,500","18,500",1,1,https://www.doguiklimlendirme.com/d/isi-geri-kazanim-cihazlari/four-rter-rotorlu-tip-enerji-geri-kazanim-cihazi,0,1,1,1,10,0,1040,506.25,225,1200,1300,1012.5,https://www.doguiklimlendirme.com/d/heat-recovery-units/four-rter-rotary-type-heat-energy-recovery-unit,1,400,K41.200.1.T.X,RTER-200-1-TOP,Metal Black,DOGU HVAC,1,2125,1,1,1,1030,ROTARY TYPE HEAT RECOVERY UNIT-RTER-1 switchable duct connection(top or side) and interchangeable service doors with new fan positioning acc.to new regulation for Rotary wheeled units(to prevent the leakage of exhaust air to suplly air).,1,900,1155,1,1,Metal White,100,1875,1412,2025,2250,800,Gray Plastic,3530 K41.140.1.T.X,1193,0.0117,-0.000006,1445,380,1,1,9400,1,797.7777778,1,"ISO Epm2,5",200,257.45,1,1,14.6,1,1,"13,500","13,500",1,1,https://www.doguiklimlendirme.com/d/isi-geri-kazanim-cihazlari/four-rter-rotorlu-tip-enerji-geri-kazanim-cihazi,0,0,1,1,10,0,10,400,191,1840,1750,800,https://www.doguiklimlendirme.com/d/heat-recovery-units/four-rter-rotary-type-heat-energy-recovery-unit,1,330,K41.140.1.T.X,RTER-140-1-TOP,Metal Black,DOGU HVAC,1,1700,1,1,1,0,ROTARY TYPE HEAT RECOVERY UNIT-RTER-1 switchable duct connection(top or side) and interchangeable service doors with new fan positioning acc.to new regulation for Rotary wheeled units(to prevent the leakage of exhaust air to suplly air).,1,700,870,1,1,Metal White,100,1450,1436,1600,1910,660,Gray Plastic,3590 K41.110.1.T.X,1128.4,0.02,-0.00001,1040,380,1,1,7020,1,687.7777778,1,"ISO Epm2,5",200,138.4,0,1,10.8,1,1,"11,000","11,000",1,1,https://www.doguiklimlendirme.com/d/isi-geri-kazanim-cihazlari/four-rter-rotorlu-tip-enerji-geri-kazanim-cihazi,1,1,1,1,900,890,695,368.75,178.5,780,740,737.5,https://www.doguiklimlendirme.com/d/heat-recovery-units/four-rter-rotary-type-heat-energy-recovery-unit,1,297.5,K41.110.1.T.X,RTER-110-1-TOP,Metal Black,DOGU HVAC,1,1575,1,1,1,685,ROTARY TYPE HEAT RECOVERY UNIT-RTER-1 switchable duct connection(top or side) and interchangeable service doors with new fan positioning acc.to new regulation for Rotary wheeled units(to prevent the leakage of exhaust air to suplly air).,1,600,810,1,1,Metal White,100,1325,1238,1475,1785,595,Gray Plastic,3095 K41.090.1.T.X,1019.8,0.0331,-0.00002,976,380,1,1,5460,1,687.7777778,1,"ISO Epm2,5",200,-269.81,0,1,8.4,1,1,"8,900","8,900",1,1,https://www.doguiklimlendirme.com/d/isi-geri-kazanim-cihazlari/four-rter-rotorlu-tip-enerji-geri-kazanim-cihazi,1,1,1,1,900,890,695,337.5,166,780,740,675,https://www.doguiklimlendirme.com/d/heat-recovery-units/four-rter-rotary-type-heat-energy-recovery-unit,1,265,K41.090.1.T.X,RTER-090-1-TOP,Metal Black,DOGU HVAC,1,1450,1,1,1,685,ROTARY TYPE HEAT RECOVERY UNIT-RTER-1 switchable duct connection(top or side) and interchangeable service doors with new fan positioning acc.to new regulation for Rotary wheeled units(to prevent the leakage of exhaust air to suplly air).,1,600,750,1,1,Metal White,100,1200,1238,1350,1660,530,Gray Plastic,3095 K41.050.1.T.X,1048.4,-0.1317,-0.00001,610,380,1,1,2640,1,520,1,"ISO Epm2,5",200,275.32,1,1,4.2,1,1,"4,400","4,400",1,1,https://www.doguiklimlendirme.com/d/isi-geri-kazanim-cihazlari/four-rter-rotorlu-tip-enerji-geri-kazanim-cihazi,0,1,1,1,10,0,710,280,143,850,790,560,https://www.doguiklimlendirme.com/d/heat-recovery-units/four-rter-rotary-type-heat-energy-recovery-unit,1,200,K41.050.1.T.X,RTER-050-1-TOP,Metal Black,DOGU HVAC,1,1220,1,1,1,700,ROTARY TYPE HEAT RECOVERY UNIT-RTER-1 switchable duct connection(top or side) and interchangeable service doors with new fan positioning acc.to new regulation for Rotary wheeled units(to prevent the leakage of exhaust air to suplly air).,1,400,650,1,1,Metal White,100,970,936,1120,1430,400,Gray Plastic,2340 K41.035.1.T.X,1110.4,-0.344,-0.000004,416,230,1,1,1500,1,463.3333333,1,"ISO Epm2,5",200,115.84,0,1,6.6,1,1,"2,800","2,800",1,1,https://www.doguiklimlendirme.com/d/isi-geri-kazanim-cihazlari/four-rter-rotorlu-tip-enerji-geri-kazanim-cihazi,0,1,1,1,10,0,540,250,131,850,705,500,https://www.doguiklimlendirme.com/d/heat-recovery-units/four-rter-rotary-type-heat-energy-recovery-unit,1,200,K41.035.1.T.X,RTER-035-1-TOP,Metal Black,DOGU HVAC,1,1100,1,1,1,530,ROTARY TYPE HEAT RECOVERY UNIT-RTER-1 switchable duct connection(top or side) and interchangeable service doors with new fan positioning acc.to new regulation for Rotary wheeled units(to prevent the leakage of exhaust air to suplly air).,1,315,530,1,1,Metal White,100,850,834,1000,1310,400,Gray Plastic,2085 K41.025.1.T.X,846.3,-0.0448,-0.0001,253,230,1,1,1320,1,440,1,"ISO Epm2,5",200,214.26,1,1,5.8,1,1,"2,300","2,300",1,1,https://www.doguiklimlendirme.com/d/isi-geri-kazanim-cihazlari/four-rter-rotorlu-tip-enerji-geri-kazanim-cihazi,0,0,0,0,1990,1980,10,212.5,116,0,0,425,https://www.doguiklimlendirme.com/d/heat-recovery-units/four-rter-rotary-type-heat-energy-recovery-unit,1,155,K41.025.1.T.X,RTER-025-1-TOP,Metal Black,DOGU HVAC,1,950,1,1,1,0,ROTARY TYPE HEAT RECOVERY UNIT-RTER-1 switchable duct connection(top or side) and interchangeable service doors with new fan positioning acc.to new regulation for Rotary wheeled units(to prevent the leakage of exhaust air to suplly air).,1,300,470,1,1,Metal White,100,700,792,850,1160,310,Gray Plastic,1980 K41.018.1.T.X,1017.2,0.1059,-0.0004,206,230,1,1,1000,1,422.2222222,1,"ISO Epm2,5",200,276.05,1,1,4.4,1,1,"1,500","1,500",1,1,https://www.doguiklimlendirme.com/d/isi-geri-kazanim-cihazlari/four-rter-rotorlu-tip-enerji-geri-kazanim-cihazi,0,0,0,0,1910,1900,10,187.5,106,0,0,375,https://www.doguiklimlendirme.com/d/heat-recovery-units/four-rter-rotary-type-heat-energy-recovery-unit,1,125,K41.018.1.T.X,RTER-018-1-TOP,Metal Black,DOGU HVAC,1,850,1,1,1,0,ROTARY TYPE HEAT RECOVERY UNIT-RTER-1 switchable duct connection(top or side) and interchangeable service doors with new fan positioning acc.to new regulation for Rotary wheeled units(to prevent the leakage of exhaust air to suplly air).,1,300,430,1,1,Metal White,100,600,760,750,1060,250,Gray Plastic,1900 K41.010.1.T.X,774.02,-0.6277,-0.0002,200,230,1,1,340,1,422.2222222,1,"ISO Epm2,5",200,27.256,0,1,2.8,1,1,920,920,1,1,https://www.doguiklimlendirme.com/d/isi-geri-kazanim-cihazlari/four-rter-rotorlu-tip-enerji-geri-kazanim-cihazi,0,0,0,0,1910,1900,10,175,106,0,0,350,https://www.doguiklimlendirme.com/d/heat-recovery-units/four-rter-rotary-type-heat-energy-recovery-unit,1,112.5,K41.010.1.T.X,RTER-010-1-TOP,Metal Black,DOGU HVAC,1,800,1,1,1,0,ROTARY TYPE HEAT RECOVERY UNIT-RTER-1 switchable duct connection(top or side) and interchangeable service doors with new fan positioning acc.to new regulation for Rotary wheeled units(to prevent the leakage of exhaust air to suplly air).,1,300,405,1,1,Metal White,100,550,760,700,1060,225,Gray Plastic,1900